The BETA-6 features a precision humidity sensor within a 16ft remote probe assembly. Simply plug in your humidity/dehumidifier device to the power outlet on the bottom of the BETA-6. The user can select separate “day/night” humidity settings and the photocell built into the BETA-6 will automatically start controlling your device. (Settings from 20-90% RH) Either humidifiers or dehumidifiers can be controlled by the BETA-6.

    This combination does not exist.


    TrolMaster Digital Day/Night Humidity Controller

    The BETA-6 offers indoor gardeners an economical and simple method of monitoring and controlling humidity levels within the growing area. It utilizes a highly visible and intuitive LED screen to let you know the current humidity level or max/min humidity recorded values.

    Choose your desired humidity setpoint for day and night mode. When the humidity is lower than the setpoint, the controller will automatically turn on the power supply of the humidifier for humidifying purposes and its LED indicator stays on. When the humidity is higher than the setpoint, the controller will automatically turn on the power supply of the dehumidifier for dehumidifying purposes and the corresponding LED indicator stays on.

    It can also record the max and min humidity records during use.

    A built-in photocell located on the sensor automatically detects the day and night status, controlling the humidity in day/night mode separately. A remote humidity sensor with 16 feet long cable allows close placement to the plant canopy.

    Features
    • LED Display, Easy Operation
    • Built-In Photocell Detecting Day/Night Status
    • Alternative Humidifying or Dehumidifying Function
    • Humidity Sensor with 16 ft Cable for Close Placement to Plant Canopy
    Installation
    • Mount the Controller on the wall, and place the sensor at plant height in a well-ventilated area.
    • Connect the 2-in-1 (SA-H1) sensor to the Controller.
    • Plug the Controller into a 120V NEMA 5-15 wall outlet.
    • Plug a humidifier or dehumidifier into the power outlet of the unit. Ensure that the device has a proper voltage (120V) and does not exceed its max amperage rating (10A).
    Operation Instruction

    1. Reading HumidityConnect the Humidity/Light 2-in-1 sensor (SA-H1) to the connector on the bottom. After power-on, the LED screen will display the current measured humidity level.

    2. Set Humidifying or Dehumidifying ModePress the HOME button 1 time, and the Humidifying LED indicator or the Dehumidifying LED indicator will be flashing and no digital display on the LED screen. Press UP or DOWN button to convert between Humidifying and Dehumidifying mode. The unit will automatically save the change.

    When the connected device is for humidifying purposes (such as a humidifier), please select the Humidifying mode. When the connected device is for dehumidifying purposes (such as a dehumidifier), please select the dehumidifying mode.

    3. Set Day SetpointPress the Home button 2 times, the Day Setpoint LED indicator will be flashing and the LED screen will display the current humidity Day Setpoint. Press UP or DOWN button to change the setpoint. The unit will automatically save the change.

    When the humidifying mode is selected (humidifier connected) and the humidity is detected BELOW the setpoint, the BETA-6 Controller will automatically turn on the power supply of the humidifier and its LED indicator stays on. On the contrary, when the dehumidifying mode is selected (dehumidifier connected) and the humidity is detected ABOVE the setpoint, the BETA-6 Controller will automatically turn on the power supply of the dehumidifier and its LED indicator stays on.

    4. Set Night SetpointPress the Home button for 3 times, the Night Setpoint LED indicator will be flashing and the LED screen will display current humidity Night Setpoint. Press UP or DOWN button to change the setpoint. The unit will automatically save the change.

    When the humidifying mode is selected (humidifier connected) and the humidity is detected BELOW the setpoint, the BETA-6 Controller will automatically turn on the power supply of the humidifier and its LED indicator stays on. On the contrary, when the dehumidifying mode is selected (dehumidifier connected) and the humidity is detected ABOVE the setpoint, the BETA-6 Controller will automatically turn on the power supply of the dehumidifier and its LED indicator stays on.

    5. Max/Min Recorded ValueAfter power-on, the LED screen will display the current humidity. Press UP or DOWN button, and the LED screen will display the Max or Min recorded value respectively. It will keep flashing for 1 minute and then turn back to the normal measured humidity value. While the value is flashing, long press HOME button and the Max or Min recorded value will be deleted.

    6. Restore the Factory SettingsTo restore the factory setting, press and hold HOME button before plugging the Controller into a wall outlet. After power-on, the LED screen will display “rEST” and then display “done” after 3 seconds.

    Weight (lbs)1.63
    Length (in)10.83
    Width (in)3.43
    Height (in)3.7
    Barcode6970207970458
    Input Voltage120 Volts AC
    Output SwitchRelay
    Fuse Rating10A/250V~
    AC Power Cord Length5.9 feet
    Humidity Control Range: 20-90%25-90%
    Humidity Deadband:5%